The sphere of 50mm diameter shall not fully penetrate and adequate clearance shall be kept. The standard ip ratings were originally developed by the international electrotechnical commission iec and its corresponding code is iec 60529, while the equivalent european standard is the en 60529. The first digit indicates protection against ingress of solid foreign objects. Iec 60529 for enclosures kenall manufacturing 10200 55 t street enosa i 531. Test report iec 60 529 en 60 529 degrees of protection.
This indian standard which is identical with iec 60529. Technical application guide ip codes in accordance with iec 60529 what are ip codes. An ip certification rating table or chart, has been constructed by the international electrotechnical commission iec for international use. This consolidated version of iec 60529 bears the edition number 2. The ip code, international protection marking, iec 60529, sometimes interpreted as ingress protection marking, classifies and rates the degree of protection provided against intrusion body parts such as hands and fingers, dust, accidental contact, and water by mechanical casings and electrical enclosures. Degrees of protection provided by enclosures ip code. If this test report form is used by noniecee members, the ieceeiec logo shall be removed.
Technical application guide ip codes in accordance with iec 60529. Definition of ip codes ingress protection in the iec international electrotechnical commission 60529 standards document, it specifies an international classification system for the sealing effectiveness of enclosures of electrical equipment against the intrusion into the equipment of foreign bodies i. This testing is known as ingress protection tests or ip code tests. Most backordered items can be rushed in from the publisher in as little as 24 hours. It has the status of a horizontal standard in accordance with iec guide 104. Consolidated editions the iec is now publishing consolidated versions of its publications. Ansi approval date november 3, 2004 ansiiec 605292004 degrees of protection provided by enclosures ip code identical national adoption published by.
Fingersafe ip2x per iec 60529 barriers for nq panelboards ip2x per iec 60529 standard design supports safe electrical work turn off all power supplying the panelboard before working on or inside the panelboard. Many beghelli products are rated in accordance with the iec standards and display the ip rating they have achieved. Cei en 605291997 international protection ip en 60529 f irst n umeral protection against solid bodies 0 no protection second n umeral protection against liquids 1 obect equal to or greater than 50 mm 1 vertically dripping water 2 obect equal to or greater than 12,5 mm 2 75 to 105 angled dripping water 3 obect equal to or greater. Definition of protection grades iec 60529 hammond mfg. Aug 17, 2017 abnt 2005 norma brasileira abnt nbr iec 60529 primeira edicao 30. Test result verdict trf no iecen60529a page 9 of 25 3. Din en 60529 vde 04701 ipprotection classes exract the ip code indicates the level of protection that a device, such as an electronic switch, receives from its housing. Degrees of protection provided by enclosures ip code see other formats disclosure to promote the right to information whereas the parliament of india has set out to provide a practical regime of right to information for citizens to secure access to information under the control of public authorities, in order to promote transparency and accountability in.
The nema 250 and iec 60529 standards are internationally recognized electrotechnology enclosure tests. Fingersafe ip2x per iec 60529 barriers for nq panelboards. Iec 60529 is an international standard that was created for the purpose of clarifying the capability of an enclosure to protect the contents from solid and liquid. Iec 60529 enclosure buyers beware overall conclusions. The requirements and related tests of this standard cover. It helps to classify them according to their degree of protection against solids and liquids. This is in accordance with the recommendations on professionally executed cleaning processes as stated in iec 60529. Ansiiec 605292004 degrees of protection provided by.
The ip code, or ingress protection code, iec standard 60529, sometimes interpreted as international protection code, classifies and rates the degree of protection provided by mechanical casings and electrical enclosures against intrusion, dust, accidental contact, and water. Documents sold on the ansi standards store are in electronic adobe acrobat pdf format, however some iso and iec standards are available from amazon in hard copy format. Follow all applicable laws and regulations such as osha cfr 1910, nfpa 70e, csz z462, or nom029stps. Led modules and operational equipment must, according to iec 60529, belong to a speci. Degrees of protection provided by enclosures ip code number of amendments.
Documents sold on the ansi standards store are in electronic adobe acrobat pdf format, however some iso and iec standards are available from amazon in. All equipment fully complies with iec 60529 ip code standard and all other international standards with similar tests. Corrigendum 1 amendment 2 degrees of protection provided by enclosures ip code. The international electrotechnical commission is the international standards and conformity assessment body for all fields of electrotechnology. Has the status of a basic safety publication in accordance with iec guide 104. It is published by the international electrotechnical commission iec. Download iec 60529 degrees of protection provided by enclosures ip code rar from 2 mb, iec 60529 degrees of protection provided by enclosures ip code pdf from 2 mb free from tradownload. Ansi approval date november 3, 2004 ansi iec 60529 2004 degrees of protection provided by enclosures ip code identical national adoption published by. An ip rating is a measure of an enclosure or cases ability to resist items entering it. National electrical manufacturers association 0 north 17th street, suite 1847 rosslyn, virginia 22209. In order to promote public education and public safety, equal justice for all, a better informed citizenry, the rule of law, world trade and world peace, this legal document is hereby made available on a noncommercial basis, as it is the right of all humans to know and speak the laws that govern them. Or download the pdf of the directive or of the official journal for free. Degrees of protection provided by enclosures ip code see other formats disclosure to promote the right to information whereas the parliament of india has set out to provide a practical regime of right to information for citizens to secure access to information under the control of public authorities, in order to promote transparency and. The iec 60529 standard determines how well a products enclosure protects internal working parts from ice, dust, water, and intrusion by hands, fingers, tools, and wires.
The jointed test finger of 12mm diameter, 80mm length, shall have adequate clearance from hazardous parts. Iec 60598 was created for luminaire testing and it is clear that iec 60529 is a less stringent standard, and. For example, iec 341 is now referred to as iec 600341. Ip code 4 second characteristic numeral the second characteristic numeral of the ip code determines the protection of the electrical equipment against damaging effects caused by the ingress of water. The iec site includes information about electric, electronic and electrotechnical international standards, compliance and conformity assessment for electronics and electronic equipment, and international electrical standards information.
Complete document degrees of protection provided by enclosures ip code includes all amendments and changes through reaffirmation notice, 2011. Ip code issued by the international electrotechnical. Ip iec 60529 for enclosures kenall book pdf free download link or read online here in pdf. Learn how to share your publications with your colleagues, using networking. Complete document degrees of protection provided by enclosures ip code includes all. Test report iec 60529 en 60529 degrees of protection. Against solid foreign objects of 50mm diameter and greater.
Cei en 60529 1997 international protection ip en 60529 f irst n umeral protection against solid bodies 0 no protection second n umeral protection against liquids 1 obect equal to or greater than 50 mm 1 vertically dripping water 2 obect equal to or greater than 12,5 mm 2 75 to 105 angled dripping water 3 obect equal to or greater. Ip, standing for an ingress protection is often found in the form of a table. These, in turn, summarise the scale of protection offered from estranged. As from 1 january 1997 all iec publications are issued with a designation in the 60000 series. Provides a brief comparison and explanation of some basic differences between nema 250 enclosures for electrical equipment 1,000 v maximum and iec 60529 degrees of protection provided by enclosures ip code. Ip iec 60529 for enclosures kenall book pdf free download link book now. We use cookies to make our website more userfriendly and to continually improve it.
The iec site includes information about electric, electronic and electrotechnical international standards, compliance and conformity assessment for electronics and electronic equipment, and international electrical standards. Iec 60529 for enclosures 3 kenall manufacturing 10200 55 t street enosa i 531. Abnt nbr iec 60529 20170424 degrees of protection provided by enclosures ip code. This means you can determine the exact levels of protection against moisture. Ip iec 60529 for enclosures kenall pdf book manual.
Electrotechnology enclosure testing iec 60529 and nema 250. Download standards through your account documents are normally available within a few minutes. Available language s tc 70 degrees of protection provided by enclosures. Iec 60529 luminaire ingress protection ratings ip dust rating iec 60529 enclosure standard section. All books are in clear copy here, and all files are secure so dont worry about it. All equipment fully complies with iec 60529 ip code standard and all other.